平刷王pk10免费手机版

Brand Dynamics

Home > Brand News >

Zhigao Air Conditioning Maintenance Service Center in Beijing Mentougou District :: Zhigao

时间:2019-03-18 浏览: Brand dynamic time: 2019-03-18

Zhigao air-conditioning after-sales service outlets in Mentougou District , Beijing , Zhaitang Town, Qingshui Town, Miaofeng Mountain Town. Air conditioning repair, cleaning, disinfection, installation, relocation, maintenance, security inspection, etc. For more information, please see the homepage URL and contact customer service.

Chigo air conditioning control system detection method

(1) Communication circuit

When a communication failure is detected, use a multimeter AC voltage file 250V test. If there is a voltage change between the neutral line and the signal line, and the indoor unit communication indicator continues to blink, it means that the communication is normal, otherwise the communication circuit will fail.

(2) Power module

When detecting a power module failure, the first method is to measure the power module with a multimeter diode file. The “+” and U, V, W poles, or the U, V, W, and “-” poles should have forward resistance of about 380-450Ω. If the power module fails, the second method is to use a multimeter AC voltage file to measure the voltage of the power module that drives the compressor. The voltage between any two phases should be between 0 and 160V and equal. Otherwise, the power module is damaged.

(3) Reactor

When testing the reactor, measured with a multimeter R X1, its winding resistance is about 1Ω.

(4) Compressor

When testing the compressor, first pull out the U, V, W wires with pliers and measure the voltage between the three phases. If the voltage between the three phases is the same, the compressor winding is good, otherwise the compressor winding is faulty.

Service area

  • Chigo Air Conditioning Maintenance in Mentougou District, Beijing: Knowing the Maximum Current of the Compressor

  • Chigo Air Conditioner Repair in Haidian District, Beijing: Automatic mode of air conditioner can save

  • Chigo Air Conditioning Repair, Changping District, Beijing: Noise Failure of Air Conditioner Indoor Unit

Product center

  • Chigo Air Conditioning After Sales Center in Beijing Xicheng District: Chigo Air Conditioning

  • There are many reasons why the air conditioner does not start. Let us list a few

  • Chigo Air Conditioning After Sales Center: Which parts are most likely to be affected by air conditioners?

  • Chigo Air Conditioning After Sales Center: What is DSP Control of Variable Frequency Air Conditioner?

  • Chigo Air Conditioning After Sales Center: The air conditioner has

  • Chigo Air Conditioning After Sales Center: How Air Conditioners and Dehumidifiers Work