Chigo Air Conditioning After Sales Center: The air conditioner has

时间:2019-01-26 浏览: Product Center Time: 2019-01-26

Air conditioner has dehumidification function in two modes

1. Cooling mode This is the mode that any air conditioner has, and it is also the most basic function of the air conditioner. The cooling process of the air conditioner is necessarily accompanied by dehumidification. After the humid air passes through the evaporator of the air conditioner, the temperature will drop sharply. The air humidity is in a supersaturated state. Excess water vapor is precipitated in the form of condensate and condenses on the fins of the evaporator. That is, "condensation". When the cooling mode reaches a certain equilibrium, the air humidity will drop to a certain level.

2. Independent dehumidification mode This method is called constant temperature dehumidification by the people in the industry. Its basic principle is to reheat the air cooled by the evaporator to the original temperature, and then send it into the room. In this way, the humidity of the indoor environment decreases. The down remained relatively constant. There are two methods to heat the temperature of the air outlet: one is to use electric heating components to heat the air after passing through the evaporator. This type of air conditioner is equipped with an electric heating device in the indoor unit. After the air has condensed water through the evaporator (surface low temperature), this part of the cooled air is heated by the electric heating device, so that the temperature of the air outlet and the air inlet of the air conditioner is basically the same. ; The other is to use the heat generated by the condenser to heat the dehumidified air. This type of air conditioner is equipped with two exchangers a and b, which are switched to evaporator and condenser respectively in independent dehumidification mode. Similarly, air is condensed through evaporator a (surface low temperature) and then replaced by condenser b (surface high temperature). The function of the electric heating components in the first method also keeps the temperature of the air outlet and the air inlet of the air conditioner basically the same. These two heating methods are only different from the heating device and the heating method, the latter is a pure physical method

Service area

  • Chigo Air Conditioning Maintenance in Mentougou District, Beijing: Knowing the Maximum Current of the Compressor

  • Chigo Air Conditioner Repair in Haidian District, Beijing: Automatic mode of air conditioner can save

  • Chigo Air Conditioning Repair, Changping District, Beijing: Noise Failure of Air Conditioner Indoor Unit

Product center

  • Chigo Air Conditioning After Sales Center in Beijing Xicheng District: Chigo Air Conditioning

  • There are many reasons why the air conditioner does not start. Let us list a few

  • Chigo Air Conditioning After Sales Center: Which parts are most likely to be affected by air conditioners?

  • Chigo Air Conditioning After Sales Center: What is DSP Control of Variable Frequency Air Conditioner?

  • Chigo Air Conditioning After Sales Center: The air conditioner has

  • Chigo Air Conditioning After Sales Center: How Air Conditioners and Dehumidifiers Work